| Technical Specifications | |
| Model | JUNXY-AC400V-25KW-R Charging Pile AC Load Bank Tester |
| Load Element | Stainless steel resistors |
| Load Voltage | AC400V 3P4W, 50/60Hz |
| Max Current | 32A for GB/EU charger input, 50A for US charger input |
| Rated Load Steps @AC400V 3P4W, 50/60Hz |
1A, 2A*2, 5A, 8A*2, 12A |
| Functions | AC control guidance, duty cycle measurement, S2 switch, CP voltage measurement, CC resistance measurement, R2/R3 resistance adjustment, CP pin breakage, PE pin breakage, etc., generate test report. |
| Power Factor | PF=1 |
| Load Accuracy | ±5% |
| Digital Meter | Voltage, Current, Power, Frequency and etc. |
| Power Supply | AC230V 1phase 2wire 50/60Hz
(Load bank fans & control power supply) |
| Control Mode | Manual control by HMI & PC |
| Load Input Connections | GB/EU/US 3P4W |
| Insulation Class | F |
| Fan Noise | 60dB |
| Cooling Mode | Force-air VERTICAL cooling |
| Work Mode | Continuous work |
| Protections | Over voltage/current/temperature with load removed protection and alarming, emergency stop button, fan lack of air volume protection |
| Ambient Temperature | -10℃~+50℃ |
| Dimension | 500*650*1200mm(W*D*H) |
| Weight | Around 120KG |
| Mobility | By wheels |
| Humidity | ≤95% |
| Altitude | ≤2500 meters |